Researchers Find Bactericidal Efficacy Varies by Towelette Product, Surface Area Wiped and Pathogen Strain
Disinfectant products are often used on environmental surfaces (e.g. countertops, patient beds) and patient care equipment in healthcare facilities to help prevent the transmission of healthcare-associated infections. Ready-to-use (RTU) disinfectants in the form of pre-wetted towelettes are increasingly popular among healthcare facilities. Currently, the EPA does not require disinfectant manufacturers to include a recommended maximum surface area per towelette on their product labels.
The objective of this study by
This study tested 10 disinfectant towelette products against Staphylococcus aureus strain ATCC CRM-6538 and Pseudomonas aeruginosa strain ATCC 15442 on Formica surfaces. Defined surface areas were wiped and the towelette weighed before and after wiping to determine the amount of liquid released. Bactericidal efficacy testing was also performed after wiping following standard EPA protocols.
The researchers found that disinfectant product, area of surface wiped, and strain impacted the bactericidal efficacy achieved. Disinfectant product type and area of surface wiped significantly impacted the percent of liquid released per ft2 from the towelette.
Reference: West AM, Nkemngong CA, et al. Surface area wiped, product type, and target strain impact bactericidal efficacy of ready-to-use disinfectant towelettes. Antimicrobial Resistance & Infection Control. 2018;7:122
Newsletter
Related Articles
- Bug of the Month: I'm Older Than Empires
September 16th 2025
- Top 5 Infection Prevention Articles of Summer 2025
September 16th 2025
- From Outbreak to Zoopocalypse: 11 More Must-Watch Viral Thrillers
September 15th 2025
- Debunking the Mistruths and Misinformation About COVID-19
September 15th 2025
- Bug of the Month: I Like to Hitch a Ride
September 12th 2025