Is Dry Heating or UV Disinfection Safe and Effective for Reusing N95 Respirators?
Certain disinfecting cycles can be used to extend the frequency and use of single-use respirators, but how do they affect the respirator filtration efficiency?
To remedy that lack, investigators of a study, “Filtration efficiency of N95 filtering facepiece respirators during multi-cycles of “8-hour simulated donning + disinfection” recently published in
The investigators expected the research results of 3 N95 filtering respirators to provide reference for the reusable duration and frequency of multi-cycles disinfected respirators.
Multi-cycles of dry heating and UV radiation treatments on the reused (ie, multiple 8-hour donning) N95 respirators have a minimal effect, at greater than 0.5%, on the respirator filtration efficiency.All tested N95 respirators are able to maintain filtration efficiencies equal to or greater than 95% for at least 30 hours or 4 reuse cycles of “8-hour donning + disinfection,” even at 85 L/min. Even further, a lower breathing flow rate (15 L/min) plus the exhalation valve can further extend the N95 respirator functional duration up to 140 hours or 18 reuse cycles of “8-hour donning + disinfection.” As the respirator is worn longer, aerosol penetration slowly increases in a quadratic function with a negative second-order coefficient, and the penetration increment during each cycle of 8-hour donning is less than 0.9%. Therefore, the multi-cycle N95 respirator reuse and dry heating or UV irradiation disinfection are realistic.
“However, since most current respirators use electret filters as the filtration materials, disinfection treatments in the form of aqueous solutions or steam, such as soap or hot water immersion, alcohol spraying, and high-pressure steam, will neutralize the static charge on the filters, resulting in a significant decrease in the filtration efficiency of respirators,” the investigators wrote. “Dry heating, UV radiation, and vaporized hydrogen peroxide are disinfection methods that have been proven to be effective in inactivating microorganisms without compromising the respirator filtration efficiency.”
Of these options, vaporized hydrogen peroxide, which requires specialized equipment, is overly difficult compared to microwave ovens for dry heating and ultraviolet lamps for UV radiation.
Other experts agree. “VHP is the most time-consuming, requiring a decontamination period lasting 40 to 45 minutes, not including the time required for several other critical steps in the process, including the vaporization of liquid hydrogen peroxide,”
Articles in this issue
about 3 years ago
Article
Terminal Cleaning, Including UV Sterilization, Effectiveness in Mitigating Pathogen TransmissionNewsletter
Related Articles
- Bug of the Month: I'm Older Than Empires
September 16th 2025
- Top 5 Infection Prevention Articles of Summer 2025
September 16th 2025
- From Outbreak to Zoopocalypse: 11 More Must-Watch Viral Thrillers
September 15th 2025
- Debunking the Mistruths and Misinformation About COVID-19
September 15th 2025
- Bug of the Month: I Like to Hitch a Ride
September 12th 2025