How to Be Confident in Your Disinfection: UV-C Disinfection, Dosimeter Cards, and Audits
Recent research in the American Journal of Infection Control reveals gaps in routine hospital disinfection, highlighting the need for UV-C audits. Learn how to validate UV-C dosages effectively and conduct successful audits.
Research
An audit process can be implemented at any time to assess the efficacy of autonomous UV-C disinfection in achieving comprehensive microbial reduction within hospital environments. This article provides the requisite UV-C dosages and procedural steps essential for conducting a successful audit.
UV-C Dosage and Efficacy
UV-C dosage, denoted in mJ/cm2, signifies the quantity of UV-C light administered to a specific area over a designated duration. It is a pivotal determinant of a UV-C emitting device's effectiveness.
Industry-recognized standards outline the requisite mJ/cm2 thresholds for deactivating various pathogens (Table 1).
Validating UV-C Dosages with Dosimeter Cards
Dosimeter cards serve to validate UV-C dosage, featuring a treated surface responsive to UV exposure, manifesting color changes proportional to received irradiance. Placement of dosimeter cards on high-touch surfaces within the disinfection space before commencing a UV-C disinfection cycle facilitates subsequent assessment of UV-C dosage efficacy. (Table 2)
Place the cards in locations of interest in the disinfection space with the yellow surface exposed before a UV-C disinfection cycle starts. Once the disinfection cycle is over, return to the room and review the cards for changes. It is best practice to place the cards on high-touch surfaces and mark them with testing notes. (Table 2)
Executing a UV-C Disinfection
1. Identify the top 10 high-touch surfaces in the room. In a typical hospital room, such as an operating room or patient room, these are typically bed rails, remotes, touch screens, phones, monitoring equipment, faucets, drawers, and closet handles.
2. If using an autonomous solution, map the room, navigating as closely to your chosen target surfaces as possible.
3. Disinfect the room using the appropriate disinfection intensity on your autonomous UV-C device.
Conducting a Disinfection Audit
1. Determine the 10 surfaces that you’d like to measure UV-C dosages.
2. Take 10 dosimeter cards. On each card, write the time and date of the audit and the location where it will be placed (e.g., left bed rails, right closet handle, etc.).
3. Remove the adhesive tape on the back and stick each card on its corresponding surface with the yellow exposure surface facing outward.
4. Proceed with your solution’s standard operating steps.
5. After the disinfection is complete, collect all 10 dosimeter cards.
6. Take pictures of the dosimeter cards for record-keeping purposes, as the exposure surface will fade back to yellow over time. Reusing dosimeter cards is not recommended
7. Record the audit details and the dosimeter readings in a spreadsheet. (Table 3)
Interpreting Your Results
Compare the readings with the established thresholds in Table 1. If the results are within range to disable the target pathogens in the audit space, consider setting the audit parameters as the operating parameters for your autonomous system.
If the readings do not meet your team’s desired thresholds, reevaluate your solution’s parameters based on these common scenarios:
Dosimeter cards do not show enough color change.
- Reason: Not enough UV-C dosage was delivered across the room
- Remedy: Perform disinfection at a higher intensity with new dosimeter cards
Specific area(s) did not show enough color change.
- Reason 1: Not enough UV-C dosage was delivered to specific target surfaces.
- Remedy 1: Remap the space to navigate closer to target surfaces.
- Remedy 2: Remap the space and add a program with a higher dose of UV-C at the desired area(s).
- Reason 2: Dosimeter cards were not placed within a direct line-of-sight of your solution during disinfection.
- Remedy: Reposition using a new dosimeter card and re-perform disinfection.
Summary
Effective disinfection procedures in health care settings are critical, considering potential bacterial contamination on high-touch surfaces. As such, comprehensive solutions such as autonomous UV-C disinfection utilizing dosimeter cards for validation and executing successful disinfection audits can help combat pathogens within hospital environments.
Resources to Table 1
Newsletter
Related Articles
- Bug of the Month: I'm Older Than Empires
September 16th 2025
- Top 5 Infection Prevention Articles of Summer 2025
September 16th 2025
- From Outbreak to Zoopocalypse: 11 More Must-Watch Viral Thrillers
September 15th 2025
- Debunking the Mistruths and Misinformation About COVID-19
September 15th 2025
- Bug of the Month: I Like to Hitch a Ride
September 12th 2025